On the profiler tab, the moment I click "Start recording", even before I could move the cursor away from start button, I see there is a continuous stream of change detection cycles. The Source is reported as "Window.addEventListener:message". Please see the screenshot below
How can I find what could be causing these events and hence the numerous change detection cycles?
As seen in the screenshot there is a method called "changes" listed on the right under the component details. The CasePanelComponent does even have ngOnChanges() method, so what is being referred to here by "changes" method?
Note:
I had raised the same question on StackOverflow but I haven't got any response yet, so raised it here as an issue.
Activity
eneajaho commentedon Nov 26, 2021
Hello, it looks like you have Redux Devtools installed.
It is a known issue that Redux Devtools interferes with Angular Devtools.
Check the issue here: Interferences with Redux DevTools extension
phalgunv commentedon Nov 26, 2021
Thanks @eneajaho .
Can you help with the second question about "changes" method?
eneajaho commentedon Nov 26, 2021
That is the ngOnChanges method on the component. @phalgunv
phalgunv commentedon Dec 1, 2021
@eneajaho I see "changes" method reported for components which do not have "ngOnChanges" method implemented.